Hotel room controller

Release Time:

2023-04-25 13:11

 

Function

Based on the requirements and actual situation of the hotel management's construction of the room control system, the room control system of the entire hotel is usually designed according to the following actual situations:

l  Room lighting is achieved by controlling high voltage with low voltage. Each switch uses a self-resetting form. Through program control, various lighting control scenarios are realized to achieve the purpose of user-friendly operation in the guest room;

l  The power switch has intelligent identity recognition to prevent illegal power consumption, and control permissions are set separately for personnel with different identities; when leaving the room with a card, the power of the controlled appliances can be cut off after a delay;

l  The front desk management center can preset the room temperature in the idle state, and the software reflects the room temperature, personnel situation, door opening and closing status, and service status in real time;

l  The room is equipped with service buttons such as cleaning, do not disturb, later, check-out, and emergency call. The front desk software displays and responds in real time.

l  Interface function with the hotel management system.

l  A liquid crystal touch screen centralized control method can be used to highlight the noble atmosphere.

l  A remote control can be added to control the lights.

 

Advantages

1 The system provides guests with a very user-friendly interface, requiring no instructions;

2 Using weak-to-strong electronic control technology, photoelectric isolation technology makes guest operation very safe;

3 Proactive service;

4 Quickly understand the status of the guest room, making the service more timely, reasonable, and targeted. Thus improving the quality of hotel service;

5 If there is a fault in the guest room, the waiter can promptly notify the relevant department through the network for quick repair;

6 Intelligent air conditioning control technology allows engineers and waiters to understand the operation status of each room's air conditioner and the actual room temperature through the network in a timely manner. Remote control of the air conditioner can be performed;

7 Intelligent room door status display technology can display the status of the guest room door according to various situations, and timely transmit information to relevant departments through the network to make corresponding sound and light alarms;

8 Intelligent room safe status display technology can display the status of the guest room safe according to various situations, and timely transmit information to relevant departments through the network to make corresponding sound and light alarms.

 

What functions should it have?

Stability

Hotel Room Control System As part of the low-voltage control system, considering the stability of electronic products, there should be a special research and development for the instability of electronic products " Dual Control ” Series of guest control systems: When the guest room control system malfunctions, or even when the hotel Guest Room Control System The low-voltage power is completely cut off, the original switch panel can still normally switch and control the original load, completely eliminating the long-standing concerns of hotel owners about the safety and stability of electronic products, and fully maintaining the hotel's reputation and image.

 

Scalability

In hotel Guest Control System During the renovation, the strong current system does not need to change the pipelines. It only needs to upgrade and renovate the system through the original system wiring or by simply adding system wiring (without affecting the interior decoration environment of the guest room). For example: Pulling a two-core cable from the switch panel to the lamp controller, and horizontally connecting the lamp controllers with a four-core cable completes the renovation. This will bring more system renovation and guest control system upgrade needs to more hotels that previously used traditional hotel guest control systems.

 

Fault Reporting

Electronic products inevitably malfunction during operation. The guest control system can automatically detect the working status of the terminal load, and immediately report to the monitoring center when a fault is found, which will greatly improve the efficiency of hotel system maintenance.

 

Air Conditioning Energy Saving

According to the rental status and card insertion status of hotel guest rooms, the air conditioner can automatically switch between normal, circulation, strong, energy-saving, and sleep modes, ensuring that guests receive user-friendly intelligent services while striving to achieve the hotel's green energy-saving goals.

In energy-saving mode, the hotel can set the minimum default operating temperature and intelligent temperature adjustment time frequency for the air conditioner thermostat, and the thermostat can intelligently and humanely adjust the temperature curve, and finally operate at the default temperature to achieve intelligent energy saving.

The air conditioning sleep mode can protect the health of guests and achieve energy saving.

 

Lighting Energy Saving

The room lights and bedside lights in the guest room are self-managed by the guests, and the guests will turn them off when they are not in use. However, the bathroom lights and bathroom mirror lights in the guest room are often overlooked by guests after using the bathroom, which will seriously cause waste of hotel resources. Therefore, lighting energy saving is an indispensable part of the green energy saving of the hotel guest control system.

 

Detailed Explanation

Corridor Light

Operation and location: Controlled by a door magnetic switch or a dual-control embedded spring-back large panel switch installed next to the power box.

Function Description:

l   Whether it is day or night, when the door is opened and enters the "welcome mode", the corridor light automatically lights up, creating a welcoming atmosphere, allowing guests to feel the warmth of home, and making it convenient for customers to insert their cards to get power;

l   If after entering the room 2 minutes, a valid identity recognition card is still not inserted, the corridor light will automatically turn off;

l   If a valid identity recognition card is inserted at night, entering the "check-in mode", the corridor light will light up. The left and right bedside lights will light up, and guests can turn the corridor light on and off by pressing the corridor light switch.

 

Night Light

Operation and location: Dual control by the embedded spring-back large panel switch installed on the bedside and the total control embedded touch screen switch panel.

Function Description:

l   Use the night light switch to turn the night light on and off;

l   Press the master switch to enter "Rest Mode." All lights will turn off, but controlled outlets will remain powered. If guests need to get up or get water, they can press any switch to enter "Nap Mode," automatically turning on the night light and bathroom mirror light, allowing guests to comfortably adjust to the brightness and easily find other switches they need to turn on.

 

Bathroom mirror light, bathroom light

Operation and location: Controlled by an embedded spring-return large panel switch installed at the bathroom entrance or by an infrared detector.

Function Description:

l  Use the bathroom mirror light and bathroom light switch or infrared sensor switch to turn the bathroom mirror light and bathroom light on and off.

 

Exhaust fan

Operation and location: Controlled by an embedded spring-return large panel switch installed at the bathroom entrance or automatically by the host.

Function Description:

l  Without a card inserted, the exhaust fan automatically runs every hour 5 minutes to ventilate the room.

l  With a card inserted, the exhaust fan is only controlled by the switch. , The master control does not control the exhaust fan.

 

Left and right bedside lamps

Operation and location: Controlled by an embedded touch screen switch panel installed at the bedside and automatically by the host.

l  Function description: The left and right bedside lamps (only for ordinary resistive incandescent lamps) can be steplessly dimmed;

l  After inserting a card at night and entering "Check-in Mode," the left and right bedside lamps will light up 50 % brightness, and the corridor lights and bar lights will also light up;

l  Continuously press and hold the left and right bedside lamp switches to enter the dimming process and cycle. Releasing the left and right bedside lamp dimming switches will stop the left and right bedside lamps at the current brightness;

l  When the left and right bedside lamps are on, pressing the "master switch" will turn off the left and right bedside lamps.

 

Room spotlight

Operation and location: Directly controlled by an embedded spring-return large panel switch installed at the bedside.

Function Description:

l  Controlled by a switch to turn on or off;

 

Room downlight

Operation and location: Directly controlled by an embedded spring-return large panel switch installed at the bedside.

Function Description:

l  Controlled by a switch to turn on or off;

 

Master switch

Operation and location: Controlled by an embedded spring-return large panel switch installed at the bedside.

Function Description:

l  Pressing this switch will turn off all lights in the room and automatically illuminate the "Do Not Disturb" indicator on the outdoor display box;

l  The master switch has a fluorescent display or LED indicator light with dim display.

 

Doorbell

Operation and location: Controlled by a multi-function display switch outside the door.

Function Description:

l  Pressing the doorbell switch will emit a pleasant "ding-dong" sound, prompting guests that someone is visiting;

l  When the guest presses the master control to enter "Rest Mode" and activates "Do Not Disturb," or when the guest directly activates "Do Not Disturb," the doorbell will be disabled. The doorbell will only resume normal operation after "Do Not Disturb" is deactivated.

 

Card power switch

Operation and location: Installed on the power switch panel at the entrance inside the door.

Function Description:

l  Power is only available after inserting a room card. Room functions are disabled without a card inserted;

l  It connects to the door lock system and uses the same protocol. Only this card can power the room, and the entry personnel's identity can be displayed and recorded on the computer terminal in the guest room center;

l  Relevant connection data is provided by the door lock manufacturer.

 

Guest room door magnetic and wardrobe door magnetic switch

Operation and location: Installed on the top of the door frame and the top of the guest room door, and controlled by the door magnet and wardrobe door and next to the wardrobe.

Function Description:

l  The network control program displays the opening and closing status of the guest room door;

l  After inserting the room card, if the room door is not closed 5 minutes later, it will enter " warning status ” An alarm will be triggered on the network control program (i.e., the door icon will flash). It will automatically return to normal after the door is closed;

l  If the room door is opened and the room card is not inserted within 30 seconds, it will enter " warning status ” An alarm will be triggered on the network program (the guest icon will flash, and there will be a voice alarm). It will automatically return to normal after the door is closed;

l  Opening the room door will automatically cancel the "Please Wait" display, and the "Please Wait" switch will be disabled. After closing the room door, the "Please Wait" switch will resume normal function;

l  Room door open / and close information is recorded on the server and can be classified for query, printing, and report generation.

 

Request cleaning

Operation and location: Controlled by an embedded spring-return large panel switch installed next to the card power switch or at the bedside.

Function Description:

l  When pressing this switch, the switch LED indicator light will light up, and the icon on the outdoor multi-function panel will light up. This signal is transmitted to the guest room center computer via a dedicated network. Conversely, the icon display on the relevant workstation computer will disappear;

l  When the room cleaning is activated, if the room card is removed, the room cleaning display remains unchanged; it can only be cleared manually by pressing this switch when the service staff cleans the room, effectively evaluating the service efficiency of the service staff;

l  After pressing the cleaning room switch, the do not disturb indicator will automatically turn off.

 

Do Not Disturb

Operation and location: Controlled by an embedded spring-return large panel switch installed next to the card power switch and at the bedside.